테이퍼 부시 HTD 타이밍 풀리 are organized here by the selection variables an engineer or buyer actually needs: profile, tooth count, belt width, shaft interface and construction. Taper-bush HTD pulley families with catalogue-defined bush codes and bore ranges.
이 제품군을 탐색하는 방법
먼저 벨트의 전체 명칭을 확인하십시오. 그런 다음 톱니 수 또는 필요한 속도비, 벨트 폭 및 축/장착 방식을 확인하십시오. 외경만으로 선택하지 마십시오. 교체용 벨트인 경우, 제품을 비교하기 전에 양쪽의 허브 돌출부와 플랜지 배열을 기록해 두십시오.
아래 제품 카드를 클릭하면 카탈로그 표, 치수 참조 및 견적 요청 지침이 포함된 상세 페이지로 이동합니다. 아래 제품 표를 사용하여 상세 제품 페이지를 열고 해당 제품군에서 사용 가능한 카탈로그 구성을 비교해 보세요.

제품 옵션

HTD 14M-115 Taper Bush Timing Pulley
14M HTD timing pulley in the 14M-115 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 14M-170 Taper Bush Timing Pulley
14M HTD timing pulley in the 14M-170 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 14M-40 Taper Bush Timing Pulley
14M HTD timing pulley in the 14M-40 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 14M-55 Taper Bush Timing Pulley
14M HTD timing pulley in the 14M-55 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 14M-85 Taper Bush Timing Pulley
14M HTD timing pulley in the 14M-85 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 5M-15 Taper Bush Timing Pulley
5M HTD timing pulley in the 5M-15 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 8M-20 Taper Bush Timing Pulley
8M HTD timing pulley in the 8M-20 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 8M-30 Taper Bush Timing Pulley
8M HTD timing pulley in the 8M-30 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 8M-50 Taper Bush Timing Pulley
8M HTD timing pulley in the 8M-50 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →
HTD 8M-85 Taper Bush Timing Pulley
8M HTD timing pulley in the 8M-85 taper-bush family. Select tooth count and the matching bush code from the catalogue row.
자세히 보기 →When a Taper Bush Arrangement Helps
A taper-bush pulley can simplify standardized shaft mounting when the pulley series, bush code and maximum bore all align. The bush number is not independent of the pulley row, so verify tooth count, construction type, bush and maximum bore together.

호환성 및 측정 검사
주문하기 전에 톱니 시스템, 톱니 개수, 작동 폭, 보어/부시, 허브 돌출부, 플랜지 배열 및 벨트 라인 위치를 확인하십시오. 중요한 맞춤 또는 런아웃 요구 사항이 있는 경우 도면에 기록하십시오. 교체 작업의 경우, 기존 풀리의 마모로 인해 측정값이 왜곡될 수 있는지 검사하고 샤프트 또는 스페이서 배열이 변경되었는지 확인하십시오.

관련 엔지니어링 지침
사용하세요 HTD 풀리 선택 가이드 전체 의사 결정 순서는 다음을 참조하십시오. 벨트와 풀리의 일치 벨트 코드를 알면 검토하십시오. 애플리케이션 페이지 기기별 점검을 위해.
Taper Bush HTD Timing Pulleys FAQ
견적을 위해 필요한 정보는 무엇입니까?
벨트/프로파일, 톱니 수, 벨트 폭, 샤프트 또는 부싱 세부 정보, 수량 및 목적지를 보내주십시오. 허브, 플랜지, 재질, 마감 또는 검사 요건이 비표준인 경우 도면을 첨부해 주십시오.
오래된 풀리를 사진으로 식별할 수 있을까요?
사진은 구조를 파악하는 데 도움이 되지만, 교체품을 확정하려면 치수와 호환 벨트의 표시가 필요합니다.
공칭 피치가 같은 모든 풀리는 서로 호환 가능한가요?
아니요. 정확한 치형과 기계적 접촉면을 확인하십시오. 명목상의 피치만으로는 교체 여부를 결정하기에 충분하지 않습니다.
Treat the Bush and Pulley as One Mounting Decision
A taper-bush HTD pulley is selected from the supported pulley series together with the bush designation and actual shaft. The bush should not be chosen as a visually similar accessory after the pulley has already been fixed.
For maintenance replacement, photograph the installed orientation, note the bush marking and record removal space before disassembly. Include the shaft diameter and any keyway condition on the RFQ so the mounting system can be reviewed as a complete interface.
Taper-Bush Availability Is Controlled by the Product Row
The taper-bush HTD catalogue does not simply duplicate every straight-bore series. The available taper-bush range on this site covers 5M-15; 8M-20, 8M-30, 8M-50 and 8M-85; and 14M-40, 14M-55, 14M-85, 14M-115 and 14M-170 families. Within those families, the supported bush designation changes with tooth count and construction type. The bush code must therefore stay attached to the exact pulley row during RFQ and ordering.
A stated maximum bore is a limit for the referenced bush arrangement, not the buyer’s ordered shaft diameter. Send the actual shaft size and required bush designation or ask for the interface to be checked from the shaft data.

Why the Bush and Pulley Must Be Reviewed Together
The taper interface positions and grips the pulley on the shaft, while the pulley body establishes the belt plane and tooth geometry. Changing the bush family, hub style or axial position can alter the installation even when the HTD pitch and tooth count are unchanged. Check guard clearance, adjacent bearings and the required belt centerline before releasing a replacement.
For a maintenance job, record the existing bush marking before disassembly. If the marking is unreadable, measure the shaft and pulley envelope and send photographs instead of guessing a bush number from apparent size.
Taper-Bush RFQ Checklist
HTD pitch, width series and tooth count.
Existing bush code where known, plus the actual shaft diameter.
Hub orientation, flange position, belt line and available clearance.
Quantity, drawing revision and any material, finish or inspection requirements.
Do Not Substitute Bush Codes by Appearance
Taper bushes with similar outside form can differ in size, bore range and installation dimensions. Read the bush designation from the existing component when possible and verify it against the exact pulley row. If the old marking is unreadable, send the shaft diameter and clear dimensional photographs instead of selecting a bush by visual similarity.
When a new bush/pulley pair is being specified, check axial clearance and the intended belt centerline at the same time. The mounting method solves the shaft connection; it does not remove the need to verify pulley width, tooth count, flange arrangement and machine clearance.
Service and Reordering
Keep the pulley code, tooth count, bush designation and actual shaft diameter together in the maintenance record. If a bush is changed during repair, update the record so a future replacement does not assume the original mounting remains in service. Also note the orientation of the hub and the belt-line datum used by the machine.
For mixed taper-bush orders, place each pulley/bush combination on its own line. Similar-looking bush parts should not be packed or recorded only by shaft diameter because the bush series is part of the interface definition.
