HTD 타이밍 풀리 기호
HTD 타이밍 풀리 엔지니어링

Timing Pulley Bore and Shaft Interface Guide

견적 요청

Timing Pulley Bore and Shaft Interface Guide: Capture bore, fit, keyway or bush, hub projection and axial belt-line references.

What This Decision Controls

Capture bore, fit, keyway or bush, hub projection and axial belt-line references. The decision should be documented with the belt designation, product code or drawing because a timing pulley is part of a drive system. A visual match does not prove tooth compatibility or shaft fit.

Timing Pulley Bore and Shaft Interface Guide

Recommended Workflow

Start with the mating belt and drive requirement. Confirm pitch/profile, tooth count and working width. Then check the shaft interface, hub and flange envelope, material and any controlled inspection requirement. For a replacement, measure the old part from both sides and record the belt line relative to a stable machine datum.

HTD 타이밍 풀리 선택 흐름

Common Errors to Avoid

  • Choosing by outside diameter while ignoring the tooth system.
  • Assuming that every curvilinear profile with the same nominal pitch is interchangeable.
  • Measuring only one side and missing hub projection or an offset belt line.
  • Leaving bore fit, keyway, bush code or inspection requirements until after quotation.
  • Using a universal belt-tension or tolerance value without the machine and belt design basis.

Use the Guide in an RFQ

Once the key variables are captured, open the HTD 제품군, compare the relevant application context, or send the drawing and order details through the form below.

Discuss Your Drive

Finish the Shaft Interface Only After the Pulley Family Is Fixed

Confirm HTD family, width series and tooth count before finalizing bore or taper-bush details. This prevents a convenient shaft connection from steering the order toward the wrong belt-side geometry.

Record shoulders, spacers, keyway information and axial location from the actual machine. Any fit or tolerance not defined by the selected catalogue row should be controlled on the drawing.

Finish the Shaft Interface After the Belt-Side Geometry

First fix pitch family, width and tooth count. Then define shaft diameter, finished bore or supported taper bush, keyway or other locking detail where applicable, hub projection and belt centerline. These are installation variables, not tooth-profile variables.

When the decision involves an existing machine, keep measurements, catalogue values and new project requirements separate. This prevents a field measurement from being silently treated as a nominal dimension or a desired change from being mistaken for a standard family feature.

HTD 타이밍 풀리 치수 참조

Use the Drawing and Table Together

Construction drawings explain the symbols and relationships. The row-specific table provides the actual values for the selected model. Do not scale the illustration or transfer dimensions from another width or tooth count simply because the product looks similar.

Where the catalogue does not control a required fit, runout, tolerance, finish or document, put that requirement on the project drawing or RFQ and make it part of the order review.

Release Checklist

Keep the belt/profile identity, working width, tooth count, mounting definition, quantity and drawing revision on the same technical order line. Add machine duty for a new drive or clear photographs and measurements for replacement work. This gives purchasing a configuration that can be checked instead of a collection of disconnected dimensions.

What This Guide Does Not Replace

This guide helps organize the selection and measurement process; it does not replace the exact product row, belt data or project drawing. If a required power, torque, speed, fit, tolerance or service limit is not stated in the relevant catalogue table or approved drawing, keep it as a design or RFQ input and verify it for the actual drive.

That boundary is useful during procurement because it prevents a general engineering explanation from being quoted later as if it were a guaranteed value for every HTD pulley configuration.

Apply the Bore And Shaft-Interface Review to a Real Machine

Collect shaft diameter, fit or tolerance when controlled, key/bush method, hub projection and axial datum. Use the catalogue or dimension drawing to name features consistently, then separate measured machine values from catalogue values. The working rule is simple: a bore number without the mounting method and hub geometry does not define the installed interface. If the old component is worn or modified, treat its measurements as field data rather than assuming they are the original nominal dimensions.

For replacement work, compare both front and rear hub relationships and note which face establishes the belt line. For a new design, record the speed relationship, center distance, duty and installation envelope before the product code is selected. This keeps the selection traceable when the drive is serviced later.

Use the Drawing to Close Remaining Gaps

A standard product row can define pitch family, tooth count and many envelope dimensions, but project-specific shaft fits, key details, hub changes, finishes or inspection limits may still require a drawing. Show the machine datum and the dimensions that actually control assembly rather than filling the drawing with uncontrolled reference dimensions.

If two catalogue configurations appear possible, identify what is still unknown and measure that feature directly. This is more reliable than choosing the configuration with the closest outside diameter or the most familiar photograph.

HTD pulley component and interface reference for bore and shaft-interface review

Release Data for Bore And Shaft-Interface Review

Keep the complete product identity with the purchase line: HTD family, width series, tooth count, bore or bush, quantity and the drawing revision where one is used. Add order-specific material, finish, inspection or documentation requirements separately. This makes later replacement work easier because the accepted configuration can be recovered without reconstructing the decision from email history.

Release the Shaft Interface From a Drawing

Use a controlled drawing whenever bore fit, keyway geometry, hub projection or axial belt position affects assembly. Record the shaft diameter and tolerance, any key or locking element, available shoulder length, and the position of the belt centerline relative to the machine datum. If an existing pulley is being replaced, measure both sides before removal where possible. The catalogue row defines the pulley family; the released interface drawing should define the project-specific shaft connection.